Dark Light

H1Z2Z2-K Solar Cable 4.0mm 9m Red (Second-Hand)

Availability:

In stock


Technical Data
Temperature range
-40°C to +90°C
max. temperature at conductor +120°C

Short circuit temperature
200°C (short circuit duration up to 5 s)

Nominal voltage
VDE 600/1000 V AC
1800 V DC conductor/conductor

AC test voltage
10000 V

Minimum bending radius
flexing 10x cable Ø
fixed installation 4x cable Ø

Highest permissible Voltage
• DC: Conductor/Conductor 1,8 kV, Conductor/Earth 0,9 kV
• AC: Conductor/Earth 0,7 kV
• Three phase: Conductor/Conductor 1,2 kV

Cable Structure
Tinned copper conductor, to DIN VDE 0295 cl.5, fine wire, IEC 60228 cl.5
Core insulation of cross-linked Polyolefin
Core identification white
Outer sheath of cross-linked Polyolefin
Sheath colour: see table below
With meter marking

Properties
Double-insulated
Ozone resistant acc. to EN 50396
Weather und UV resistant acc. to HD 605/A1
Halogen-free acc. to DIN EN 50267-2-1, EN 60684-2
Resistant to acid and bases acc. to EN 60811-2-1
Flame retardant to DIN VDE 0482-332-1-2
DIN EN 60332-1-2 / IEC 60332-1-2
Very robust and abraison-resistant sheath acc. to DIN EN 53516
Anticipated service life: 25 year
Hydrolysis and ammoniac resistant

Length: 9 meter

CONDITION:
Used.

WARRANTY
7-day satisfaction gaurantee, no further warranty provided.

R 70.00 Inc VAT

Technical Data
Temperature range
-40°C to +90°C
max. temperature at conductor +120°C

Short circuit temperature
200°C (short circuit duration up to 5 s)

Nominal voltage
VDE 600/1000 V AC
1800 V DC conductor/conductor

AC test voltage
10000 V

Minimum bending radius
flexing 10x cable Ø
fixed installation 4x cable Ø

Highest permissible Voltage
• DC: Conductor/Conductor 1,8 kV, Conductor/Earth 0,9 kV
• AC: Conductor/Earth 0,7 kV
• Three phase: Conductor/Conductor 1,2 kV

Cable Structure
Tinned copper conductor, to DIN VDE 0295 cl.5, fine wire, IEC 60228 cl.5
Core insulation of cross-linked Polyolefin
Core identification white
Outer sheath of cross-linked Polyolefin
Sheath colour: see table below
With meter marking

Properties
Double-insulated
Ozone resistant acc. to EN 50396
Weather und UV resistant acc. to HD 605/A1
Halogen-free acc. to DIN EN 50267-2-1, EN 60684-2
Resistant to acid and bases acc. to EN 60811-2-1
Flame retardant to DIN VDE 0482-332-1-2
DIN EN 60332-1-2 / IEC 60332-1-2
Very robust and abraison-resistant sheath acc. to DIN EN 53516
Anticipated service life: 25 year
Hydrolysis and ammoniac resistant

CONDITION:
Used.

WARRANTY
7-day satisfaction gaurantee, no further warranty provided.

SKU: 061ed26ec6b2 Category: Tag:
error: Content is protected !!